Disposable Compatible Nonin Blood Oxygen SPO2 probes

Disposable Compatible Nonin Blood Oxygen SPO2 probes are commonly used medical accessories that work with blood oxygen measurement devices to accurately measure a patient's blood oxygen saturation and pulse rate. They emit light of a specific wavelength and calculate blood oxygen values based on differences in light absorption by haemoglobin. They come in a variety of sizes for adults, children, and newborns, and are designed for individual use to ensure hygiene and prevent cross-contamination.

    PRODUCT INTRODUCTION

    Compatible Nonin Blood Oxygen SPO2 probes Product Features

    ● Material and Safety: Made from high-quality foam and Velcro materials, such as the Nonin8500 model probe, using TPU non-toxic wires that are harmless to the human body. It also features gold-plated terminals for effective interference resistance, ensuring reliable signal transmission.

    ● Compatibility: Compatible with various pulse oximeters, Nonin8500 probe which is compatible with models like Nonin8500, 8600, 8700, and 8800.

    ● Performance Stability: Features high-performance dual shielding, with special alloy conductors extending cable lifespan by 3 to 5 times, ensuring stable signal transmission in various environments, reducing interference, and guaranteeing accurate measurement results.

    ● User-Friendly Design: The probe is lightweight and easy to operate and secure, such as the infant wrap probe, which comes with special adhesive tape. Following the guidelines, it can be conveniently attached to the newborn's foot.


    Compatible Nonin Blood Oxygen SPO2 probes Technical Specifications

    ● Wavelength: Red light is typically 660nm, while infrared light is available in various specifications such as 880nm, 905nm, and 940nm.

    ● Measurement Range: Pulse rate (BPM) ranges from 30 to 245, and oxygen saturation (% SpO₂) ranges from 0% to 100%.

    ● Operating Environment: Storage temperature: -10°C to +40°C; operating temperature: +5°C to +40°C; humidity ≤85%; suitable for high-pressure environments ranging from 86 kPa to 106 kPa.


    Compatible Nonin Blood Oxygen SPO2 probes Target Population and Application Site

    ● Adult single-use pulse oximetry probe: Suitable for adults weighing ≤30 kg, applicable to the index finger or other fingers.

    ● Paediatric single-use pulse oximetry probe: Suitable for children weighing 10 kg to 30 kg, applicable to the index finger or other fingers.

    ● Newborn/Adult Single-Use Pulse Oximetry Probe: Suitable for newborns weighing ≥3 kg and adults weighing ≤40 kg. For newborns, it can be placed on the sole of the foot; for adults, it is placed on the finger.

    ● Infant/Preterm Infant Single-Use Pulse Oximetry Probe: Suitable for infants or preterm infants weighing ≥15 kg, placed on the big toe.

    2